Part Number STH025 2/14 53
Preventative Maintenance Cleaning
Procedure
This procedure cleans all components in the water
flow path, and is used to clean the ice machine
between the bi-yearly cleaning/sanitizing procedure.
Ice machine cleaner is used to remove lime scale and
mineral deposits. Ice machine sanitizer disinfects and
removes algae and slime.
NOTE: Although not required and dependant on your
installation, removing the ice machine top cover may
allow easier access.
1. Ice must not be on the evaporator during the
clean/sanitize cycle. Follow one of the methods
below:
Press the power switch at the end of a harvest
cycle after ice falls from the evaporator(s).
Press the power switch and allow the ice to melt.
2. Open the front door to access the evaporator.
!
Caution
Never use anything to force ice from the
evaporator. Damage may result.