Manitowoc I0320 Especificaciones Pagina 181

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 272
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 180
Part Number STH025 2/14 181
ICE MACHINE DOES NOT CYCLE INTO HARVEST
Will not harvest symptoms
Low ice production
Thick ice in bin
Large sheet of ice on evaporator
Harvest cycle doesn’t start
Freeze cycles are longer than published cycle
times
If ice is on the evaporator initiate a manual harvest
cycle by performing the following keystrokes.
Press Menu
Scroll down to Service and press right arrow
Scroll down to Manual Harvest and press right
arrow - A new freeze cycle will start after the
manual harvest cycle is complete.
NOTE: Ice must be off the evaporator before starting
the procedure.
1. Disconnect the ice thickness probe from the
control board, then reboot the control board by
disconnecting and reconnecting line voltage to the
ice machine.
2. Wait six minutes into the freeze cycle (timing
starts when the water pump energizes).
Ice Machine cycles into harvest normally - Perform
steps 1 & 2 on
page 179 to test ice thickness
probe and control board.
Ice machine will not cycle into harvest - Replace
control board.
Vista de pagina 180