104 Part Number STH025 2/14
Control Board Timers
The control board has the following non-adjustable
timers:
The ice machine is locked into the freeze cycle for
6 minutes before a harvest cycle can be initiated.
This can be overridden by initiating a manual
harvest. Refer to “Manual Harvest” on page
87
The maximum freeze time is 60 minutes at which
time the control board automatically initiates a
harvest sequence.
The maximum harvest time is 3.5 minutes. The
control board automatically initiates a freeze
sequence when these times are exceeded.
The maximum water fill is 12 minutes.