Manitowoc I0320 Especificaciones Pagina 180

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 272
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 179
180 Part Number STH025 2/14
5.
Ohm Ice Thickness Probe
NOTE:
Verify meter leads are properly connected to
VOM with the red meter lead connected to positive &
the black meter lead connected to negative
Disconnect Ice Thickness Probe from control
board
Connect red meter lead to the red wire and the
black meter lead to the black wire - Normal
readings = 1.4 to 2.5 K's.
Reverse leads - Connect black meter lead to the
red wire, red meter lead to the black wire - Normal
readings = 1.2 to 1.5 K's.
6.
Check control board voltage
Set VOM to DC voltage scale - Check voltage
across the top and bottom pin - Normal readings =
3.25 to 3.35 VDC.
Pass Ohm values are within range - Check control board
voltage at the ice thickness probe connection.
Fail
Replace ice thickness probe.
Pass Control board voltage is normal
Fail
Replace control board
Vista de pagina 179
1 2 ... 175 176 177 178 179 180 181 182 183 184 185 ... 271 272

Comentarios a estos manuales

Sin comentarios