106 Part Number STH025 2/14
4. Freeze
On Off Off
Cycles
Off then
On two
more
times
Off On On
May Cycle
On/Off
Until Ice Contact
w/Ice Thickness Probe
Harvest Sequence
5. Water Purge
On On On Off On On On
May Cycle
On/Off
Factory
Set at
45 Seconds
6. Harvest
Off On On Off Off On On
May Cycle
On/Off
Bin Switch
Activation
7. Automatic
Shut-Off
Off Off Off Off Off Off Off Off
Until 3 Minute Delay
Expires and Bin Switch
Re-closes
* NOT USED ON ALL MODELS
Self Contained Air & Water-Cooled Models (Continued)
Ice Making
Sequence of
Operation
Water
Pump
Harvest
Valve(s)
Air
Pump(s)*
Water
Inlet
Valve
Water
Dump
Valve
Contactor
Coil
Compressor
Condenser
Fan Motor
Length
of Time