Manitowoc I0320 Especificaciones Pagina 127

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 272
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 126
Part Number STH025 2/14 127
Wait 5 minutes into the
freeze cycle.
Compare temperatures of
evaporator inlet and
evaporator outlet.
Inlet T3 __________° F (°C)
Outlet T4 ________ ° F (°C)
Difference
T3 & T4__________ ° F (°C)
Reference “Comparing
Evaporator Inlet and Outlet
Temperatures - Self-contained &
Remote Condenser Single
Expansion Valve Machines” on
page 147
Inlet and outlet
within 7° F (4°C)
of each other
Inlet and outlet
not within 7° F (4°C)
of each other
-and-
Inlet is colder than
outlet
Inlet and outlet
within 7°F (4°C)
of each other
-or-
Inlet and outlet
not within 7°F (4°C)
of each other
-and-
Inlet is warmer than
outlet
Inlet and outlet
within 7°F (4°C)
of each other
SINGLE EVAPORATOR, SINGLE EXPANSION VALVE
SELF CONTAINED AIR, WATER & REMOTE CONDENSER
Operational Analysis 1 2 3 4
Vista de pagina 126
1 2 ... 122 123 124 125 126 127 128 129 130 131 132 ... 271 272

Comentarios a estos manuales

Sin comentarios