Manitowoc I0320 Especificaciones Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 272
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
Part Number STH025 2/14 43
Step 1 Open the front door to access the evaporator
compartment. Ice must not be on the evaporator
during the clean/sanitize cycle. Follow one of the
methods below:
Press the power switch at the end of a harvest
cycle after ice falls from the evaporator(s).
Press the power switch and allow the ice to melt
.
Step 2 Remove all ice from the bin/dispenser.
Step 3 Press the clean switch. Water will flow
through the water dump valve and down the drain.
Wait until the water trough refills and the display
indicates add solution (approximately 1 minute), then
add the proper amount of ice machine cleaner.
!
Caution
Never use anything to force ice from the
evaporator. Damage may result.
Model Amount of Cleaner
I0300/I0320/I0520 3 ounces (90 ml)
I0450/I0500/I0600/I0850
I0906/I1000/I1100/I1200
5 ounces (150 ml)
I1400/I1800 9 ounces (265 ml)
Vista de pagina 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 271 272

Comentarios a estos manuales

Sin comentarios