Manitowoc I0320 Especificaciones Pagina 139

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 272
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 138
Part Number STH025 2/14 139
One Evaporator, Two TXV 30” Models
Tubing routing for one evaporator with two TXV’s is
different. The evaporator has two inlets and outlets. Fill
pattern varies depending on which circuit is affected,
Extremely Thin at the Evaporator Outlet will first be
visible either 1/4 or 3/4 of the way down the
evaporator.
Extremely Thin at the Evaporator Inlet will show at
the bottom of the evaporator or 1/2 of the way down
depending on the circuit affected.
ICE
Thin at Inlet
Inlet
Outlet
ICE
ICE
ICE
ICE
Inlet
Outlet
Thin at Outlet
Vista de pagina 138
1 2 ... 134 135 136 137 138 139 140 141 142 143 144 ... 271 272

Comentarios a estos manuales

Sin comentarios