Manitowoc QF0800 Especificaciones Pagina 86

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 308
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 85
86 Part Number 80-1230-9 6/08
Water Level Probe Removal
1. Place the toggle switch in the OFF position, turn
off the water supply and disconnect electrical
power to the ice machine.
2. Disconnect water supply line at float valve quick
disconnect by depressing stainless steel lever.
3. Pull up on water level probes to remove.
4. Disconnect wires from water level probes or
control board.
QF0400
Water Reservoir Cover Removal
1. Place the toggle switch in the OFF position, turn
off the water supply and disconnect electrical
power to the ice machine.
2. Remove water level probes.
3. Remove water float valve coil.
4. Depress coil and rotate 1/4 turn counterclockwise.
5. With coil wires attached, lift coil off enclosure
tube.
6. Remove top cover from float reservoir.
WATER LEVEL
PROBES
Vista de pagina 85
1 2 ... 81 82 83 84 85 86 87 88 89 90 91 ... 307 308

Comentarios a estos manuales

Sin comentarios