150 Part Number 80-1230-9 6/08
SafeGuard Modes
NO WATER
During the Freeze cycle if the water level probe opens
or remains open for more than
90 continuous seconds*, the ice machine:
1. De-energizes the compressor and/or gear motor.
2. Continuously flashes the Water Level Probe light.
3. Initiates a 60 minute Standby Mode.
During the Standby Mode the Water Level Probe light
will continually flash to indicate a Standby Mode.
After the 60-minute Standby Mode, the ice machine
will de-energize the Water Level Probe light and
initiate a start-up sequence.
Water contacts the water level probe:
The ice machine will continue to make ice.
Water level probe opens or remains open for more
than 90 continuous seconds*:
The ice machine will start another 60-minute Standby
Mode.
The ice machine repeats the above sequence until:
• Water contacts the water level probe.
or
• The toggle switch is moved to the OFF position.
NOTE: There are 2 control boards one remains open
for 90 seconds and the other for 30 seconds.
Replacement boards will have the 30 second time.
Indicator Light
Before 48 hours have elapsed:
After a Standby Mode has been initiated the Water
Level Probe light will flash anytime the toggle switch is
placed in the OFF position.
After 48 hours have elapsed:
The SafeGuard will be automatically erased from
memory and the Water Level Probe light will not flash.