210 Part Number 80-1230-9 6/08
ELECTRONIC BIN THERMOSTAT CONTROL
The temperature control opens the bin switch (or
toggle switch) circuit when ice contacts the sensor.
When ice no longer contacts the sensor, the circuit
closes and the ice machine starts.
Specifications
Setpoint Range: -30 to 212°F (-34 - 100°C)
Control Settings
Verify control is set properly before proceeding.
Positioning the Touchpad Jumpers
P5 JUMPER
The P5 jumper position determines if the touchpad is
locked or unlocked. The control is factory locked; to
unlock move the jumper from one pin to two pins.
Display Function Preset Settings
SP Set Point 40
DIF Differential 1
ASD
Anti-Short Cycle
Delay
1
OFS
Temperature
Offset
0
SF
Sensor Failure
Mode
0 - Nugget/Flake/Chiplet