38 Part Number 80-1230-9 6/08
Cleaning/Sanitizing Procedure
This procedure must be performed a minimum of once
every six months:
All ice must be removed from the bin/dispenser.
The ice machine and bin/dispenser must be
disassembled, cleaned and sanitized.
The ice machine produces ice with the cleaner and
sanitizer solutions.
All ice produced during the cleaning and sanitizing
procedure must be discarded.
Heavily Scaled Cleaning Procedure
Perform this procedure if you have some or all of these
symptoms.
Grinding, popping or squealing noises from the
evaporator.
Grinding noise from gearbox.
Ice machine trips speed sensor.
A Cleaning/Sanitizing Procedure must be performed
after this procedure.
!
Warning
If you do not understand the procedures or the
safety precautions that must be followed, call your
local Manitowoc Distributor or Manitowoc Ice, Inc.