Manitowoc QF0800 Especificaciones Pagina 145

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 308
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 144
Part Number 80-1230-9 6/08 145
5. If the ice damper fails to open/close at least once
in the initial 8 minute period, the control board will
initiate another safety shutdown. This sequence
will repeat until:
A. The ice machine restarts and operates
normally for 10 minutes.
B. The ice machine is unable to run normally
within 300 minutes of the initial shutdown.
If the ice machine does not run normally within 300
minutes of the initial shutdown, the control board will
lock out and require a manual reset.
The control board will flash the HES #1 light anytime
the toggle switch is placed in the off position for the
first 48 hours after the failure.
Reset Procedure
Move the ICE/OFF/CLEAN toggle switch from OFF to
ICE or disconnect and reapply power to the ice
machine.