Electrical Service
General
Voltage
The maximum allowable voltage variation is ± 10% of
the rated voltage on the ice machine model/serial
number plate at start-up (when the electrical load is
highest).
Fuse/Circuit Breaker
A separate fuse/circuit breaker must be provided for
each ice machine. Circuit breakers must be H.A.C.R.
rated (does not apply in Canada).
SN012/SN020/QF0400 115/60/1 ice machines are
factory pre-wired with a power cord and 5-15P plug
confirmation.
SN012/SN020/QF0400 230/50/1 ice machines are
factory pre-wired with a power cord, no plug is
supplied.
SF0400/SN0450/SF0600/SN0650/SF0900/SN0950/
SF1200/SN1250 ice machines are not supplied with a
power cord.
SF0900C/SN0950C/SF1200C/SN1250C/
QF2200/QF2300 with Remote Condensing Unit the
ice machine head section and remote condensing unit
are wired independent of each other. A separate
dedicated fuse/circuit breaker must be provided
for
each condensing unit. Circuit breakers must be
H.A.C.R. rated (does not apply in Canada).
All wiring must conform to local, state and national
codes.
The ice machine must be grounded in accordance
with national and local electrical codes.