Part Number 80-1230-9 10/10 27
Electrical Service
General
Voltage
The maximum allowable voltage variation is ± 10% of
the rated voltage on the ice machine model/serial
number plate at start-up (when the electrical load is
highest).
Fuse/Circuit Breaker
A separate fuse/circuit breaker must be provided for
each ice machine. Circuit breakers must be H.A.C.R.
rated (does not apply in Canada).
SN012/SN020/QF0400 115/60/1 ice machines are
factory pre-wired with a power cord and 5-15P plug
confirmation.
SN012/SN020/QF0400 230/50/1 ice machines are
factory pre-wired with a power cord, no plug is
supplied.
SF0400/SN0450/SF0600/SN0650/SF0900/SN0950/
SF1200/SN1250 ice machines are not supplied with a
power cord.
SF0900C/SN0950C/SF1200C/SN1250C/
QF2200/QF2300 with Remote Condensing Unit the
ice machine head section and remote condensing unit
are wired independent of each other. A separate
dedicated fuse/circuit breaker must be provided
for
each condensing unit. Circuit breakers must be
H.A.C.R. rated (does not apply in Canada).
!
Warning
All wiring must conform to local, state and national
codes.
!
Warning
The ice machine must be grounded in accordance
with national and local electrical codes.