Installation
Location of Ice Machine
The location selected for the ice machine must meet
the following criteria. If any of these criteria are not
met, select another location.
The location must be indoors.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 45°F (7°C),
but must not exceed 110°F (43°C).
The water temperature must be at least 45°F
(7°C), but must not exceed 90°F (32°C).
The location must not be near heat-generating
equipment or in direct sunlight.
The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
The location must allow enough clearance for
water, drain and electrical connections in the rear
of the ice machine.
The location must not obstruct airflow through or
around the ice machine. Refer to the chart below
for clearance requirements.
RFC Condensing Units ONLY - Interconnecting
wiring (115/60/1 or 230/50/1) is required between
the ice machine and condensing unit to energize
the contactor coil.
The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C).
Failure caused by exposure to freezing
temperatures is not covered by the warranty. See
“Removal from Service/Winterization”
!
Warning
PERSONAL INJURY POTENTIAL
Remove all ice machine panels before lifting and
installing.