Part Number 80-01111-9 7/10 61
Step 1 Set the toggle switch to the OFF position after
ice falls from the evaporator at the end of a Harvest
cycle. Or, set the switch to the OFF position and allow
the ice to melt off the evaporator.
Step 2 Remove all ice from the bin.
Step 3 To start a cleaning cycle, move the toggle
switch to the WASH position.
Step 4 Wait until water flows over the evaporator
(about three minutes) then add the proper amount of
Manitowoc Ice Machine Cleaner to the water trough.
Step 5 Wait until the clean cycle is complete
(approximately 45 minutes) then place the toggle
switch in the OFF position, disconnect power and
water supplies to the ice machine.
!
Caution
Never use anything to force ice from th e
evaporator. Damage may result.
Model Amount of Cleaner
QM20/QM30 45 ml
!
Warning
Disconnect electric power to the ice machine
at the electric switch box before proceeding.