164 Part Number 80-01111-9 7/10
Bin Thermostat
QM20/QM30
Function
The bin thermostat stops the ice machine when the bin
is full.
The level of ice in the ice storage bin controls the ice
machine shut-off. When the bin is full, ice cubes
contact the bin thermostat bulb holder, which cools
down and opens the bin thermostat to stop the ice
machine. The ice machine remains off until enough ice
has been removed from the bin. This causes the
thermostat bulb holder to warm and closes the bin
thermostat, restarting the ice machine.
Specifications
Check Procedure
Control Setting
Bin Thermostat Cut in: 40°F (4.5°C)
Cut out: 34°F (1.0°C)
! Warning
High (line) voltage is appl ied to the control bo ard
(terminals #8 an d #2) at all times. Re moving the
control board fuse or moving the toggle switch to
OFF will not remo ve the power supplied to the
control board.
! Warning
Disconnect electrical pow er to th e entire ice
machine before proceeding.