Part Number 80-01111-9 7/10 199
Component Specifications
Main Fuse
Bin Switch
QM45/Q130/Q170/Q210/Q270
Bin switch operation is controlled by the movement of
the ice damper.
Bin Thermostat
QM20/QM30/SM50
ON/OFF/WASH Toggle Switch
Single-pole, double-throw switch. The switch is
connected into a varying low D.C. voltage circuit.
Fan Control Cycle
QM45/Q130/Q170/Q210/Q270
Volt Amp
QM20/QM30 250 8
QM45/SM50/
Q130/Q170/Q210/Q270
250 10
Control Setting
Bin Thermostat
Cut in: 40°F (4.5°C)
Cut out: 34°F (1.0°C)
Model
Cut-in
(Close)
Cut-out
(Open)
QM45 145 psig 5 110 psig 5
Q130 250 psig 5 200 psig 5
Q170 275 psig 5 225 psig 5
Q210 275 psig 5 225 psig 5
Q270 250 psig 5 200 psig 5