Manitowoc CVD1375 Especificaciones Pagina 96

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 204
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 95
–90–
*Low pressure Control (close on pressure increase).
**The fan motor is wired through a fan cycle pressure control, therefore, it may cycle on and off.
6. Harvest Off Off Off On On On Closed **On
Bin Switch
Activation
7. Auto Shut-Off Off Off Off Off Off Off Open Off
Until Bin
Switch
Recloses
Energized Parts Chart – Model QDUAL (Continued)
Ice Making
Sequence of
Operation
Control Board Relays Condensing Unit
Length
of Time
1
Water
Pump
2
Water
Fill
Solenoid
3
Dump
Valve
4
Liquid
Line
Solenoid
5
Cool
Vapor
Valve
1
6
Cool
Vapor
Valve
2
LPCO*
Contactor
Coil
Contactor
Fan Motor
and
Compressor
Vista de pagina 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 203 204

Comentarios a estos manuales

Sin comentarios