–14–
CVD
®
Condensing Unit
Voltage
Phase
Cycle
Max. Fuse/
Circuit
Breaker
Min.
Circuit
Amps
CVD0675
208-230/1/60
208-230/3/60
230/1/50
15 amp
15 amp
15 amp
9.6
7.3
9.0
CVD0875
208-230/1/60
208-230/3/60
230/1/50
20 amp
15 amp
20 amp
11.7
8.2
11.3
CVD1075
208-230/1/60
208-230/3/60
230/1/50
25 amp
20 amp
25 amp
15.6
10.6
13.8
CVD1475
208-230/1/60
208-230/3/60
230/1/50
35 amp
25 amp
35 amp
19.6
14.1
19.8
CVD1476
208-230/1/60
208-230/3/60
30 amp
20 amp
15.3
10.8
CVD1875
208-230/1/60
208-230/3/60
230/1/50
40 amp
30 amp
40 amp
21.1
11.0
23.2
CVD2075
208-230/1/60
208-230/3/60
230/1/50
50 amp
40 amp
50 amp
27.1
19.9
29.9
!
Caution
Scroll Compressor Rotation
(CVD2075 3 Phase Only)
Correct compressor rotation must be verified at
start-up. Incorrect rotation will result in increased
compressor noise and higher than normal suction
pressure. To change rotation, reverse two lead wires
on the incoming power supply. Compressor must be
checked by a qualified technician or compressor
warranty will be void.