Harvest Sequence
5. Water Purge
On On On
30 sec.
Off
15 sec.
On
On On On
May Cycle
On/Off
Factory
Set at
45 Seconds
6. Harvest
Off On On Off Off On On
May Cycle
On/Off
Bin Switch
Activation
7. Automatic
Shut-Off
Off Off Off Off Off Off Off Off
Until Bin Switch
Re-closes & 3 min.
delay
* NOT USED ON ALL MODELS
Self Contained Air & Water-Cooled
Single Evaporator Model Energized Parts Chart (Continued)
Ice Making
Sequence of
Operation
Water
Pump
Harvest
Valve(s)
Air
Pump(s)*
Water
Inlet
Valve
Water
Dump
Valve
Contactor
Coil
Compressor
Condenser
Fan Motor
Length
of Time
Vista de pagina 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 299 300