Part Number 80-1479-3 7/10 145
Step 3 Disconnect the water level probe from the
water level probe terminal on the control board.
Important
For the test to work properly you must wait until the
Freeze cycle starts, prior to disconnecting the water
level probe. If you restart the test, you must
reconnect the water le vel pro be, rest art the ice
machine (step 1), and th en d isconnect the water
level probe after the compressor starts.
Step 3. Disconnect Probe from Control Board
Is Water
Flowing
into the
Water
Trough?
The
Water
Level
Light Is:
The Water
Inlet Valve
Solenoid
Coil Is:
Cause
Yes Off Energized
The water level
probe is
causing the
problem.
Clean or
replace the
water level
probe.
No Off Energized
The water inlet
valve is causing
the problem.
No On or Off De-energized
The control
board is
causing the
problem.