•VERTICAL EVAPORATOR DESIGN
7
Sequence of Operation
1 Before the compressor starts, the water pump
and water dump solenoid are energized for 45
seconds, to completely purge the ice machine
of old water after automatic shut-off. This feature
ensures that the ice making cycle starts with
fresh water.
The harvest valve(s) is also energized during
water purge, although it stays on for an additional
5 seconds (50 seconds total on time) during the
initial refrigeration system start-up.
When Used - The air compressor energizes for
the last 10 seconds of the cycle.
2 The compressor starts after the 45 second
water purge, and it remains on throughout
the entire Freeze and Harvest Sequences.
The water fill valve is energized at the same
time as the compressor.
At the same time the compressor starts, the
condenser fan motor (air-cooled models) is
supplied with power throughout the entire
Freeze and Harvest Sequences.
Freeze Sequence
3 The compressor is on for 30 seconds (60 seconds
initial cycle) prior to water flow, to prechill the
evaporator. The water fill valve remains on until
the water level probe is satisfied.
4 The water pump restarts after the prechill.
An even flow of water is directed across the
evaporator and into each cube cell, where it
freezes. The water fill valve will cycle on and
then off one more time to refill the water trough.
When sufficient ice has formed, the water flow
(not the ice) contacts the ice thickness probe.
After approximately 10 seconds of continual
water contact, the harvest sequence is initiated.
The ice machine cannot initiate a harvest
sequence until a 6 minute freeze lock has
been surpassed.
Figure 1. Freeze Sequence
Figure 2. Harvest Sequence
Figure 3. Automatic Shut-Off
Harvest Sequence
5 The water pump continues to run, and the water
dump valve energizes for 45 seconds to purge
the water in the sump trough. The water fill valve
energizes (turns on) and de-energizes (turns off)
strictly by time. The water fill valve energizes for
the last 15 seconds of the 45-second water purge.
After the 45 second water purge, the water fill
valve, water pump and dump valve de-energize.
6 The harvest valve(s) remains open and the refrigerant
gas warms the evaporator causing the cubes to slide,
as a sheet, off the evaporator and into the storage
bin. The sliding sheet of cubes swings the water
curtain out, opening the bin switch.
The momentary opening and re-closing of the bin
switch terminates the harvest sequence and returns
the ice machine to the freeze sequence (Step 3 - 4).
When Used - The air compressor energizes after
35 seconds and remains energized throughout
the entire harvest cycle. The air compressor will
automatically energize for 60 seconds when the
harvest cycle time exceeded 75 seconds in the
previous cycle.
Automatic Shut-off
7 When the storage bin is full at the end of a
harvest sequence, the sheet of cubes fails to
clear the water curtain and will hold it open.
After the water curtain is held open for 30
seconds, the ice machine shuts off. The ice
machine remains off for 3 minutes before
it can automatically restart.
The ice machine remains off until enough
ice has been removed from the storage bin
to allow the ice to fall clear of the water
curtain. As the water curtain swings back
to the operating position, the bin switch
re-closes and the ice machine restarts
(steps 1 - 2), provided the 3 minute
delay period is complete.