62 Part Number STH038 5/12
REAL TIME DATA
Press the Checkmark with Real Time Data highlighted
to get readings on Time & Temp, Inputs and Outputs
(be sure to use the Down arrow to reveal all the
available information).
Use the Checkmark to view:
Time and Temperature
Status Off/On - Displays stage of cycle
•Time
T1 Thermistor Temperature
T2 Thermistor Temperature
T3 Thermistor Temperature
T4 Thermistor Temperature
T3 & T4 Delta Temperature
100 hz
120 hz
Exit
Inputs
Status Off/On - Displays stage of cycle
Curtain Switch 1
Curtain Switch 2
LPCO Switch
HPCO Switch
Bin Level - Low (Optional Bin Level Probe) Status
Bin Level - Medium (Optional Bin Level Probe)
Status
Bin Level High (Optional Bin Level Probe) Status
Sensing Ice No/Yes
Water Level Low No/Yes
Water Level High No/Yes
Exit