Manitowoc I0500 Especificaciones Pagina 159

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 270
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 158
Part Number STH025 02/12 159
Touch Pad Diagnostics
Follow the control board diagnostics to the Status
Passed display. Perform the following keystrokes on
the display.
Display reads Status Passed, press the right arrow
Display reads Pass Yes, press the right arrow
Display reads Key Pad Test, press the right arrow
4. Test the functionality of all buttons on the touch
pad.
NOTE: Pushing the power button will start and stop
the ice machine. Testing it last will allow the ice
machine to continue running a freeze cycle.
As you press the buttons the first letter of the
corresponding word will flash indicating the push
button is operating correctly
Press the right arrow 5 times rapidly to exit.
5. Display reads Pass Yes and Pass No.
Press left arrow 4 times to exit to home screen.
Vista de pagina 158
1 2 ... 154 155 156 157 158 159 160 161 162 163 164 ... 269 270

Comentarios a estos manuales

Sin comentarios