Manitowoc I0500 Especificaciones Pagina 137

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 270
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 136
Part Number STH025 02/12 137
FREEZE CYCLE DISCHARGE PRESSURE
LOW CHECKLIST
Improper Installation
Refer to “Installation/Visual Inspection Checklist”
(page 131)
Air Cooled Condensers
Defective head pressure control valve, won’t
bypass (page 198)
Defective fan cycle control, stuck closed
(page 185)
Water Cooled Condensers
Water Regulating Valve out of adjustment
Water Regulating Valve Defective
Other
Undercharged
Wrong type of refrigerant
Non-Manitowoc components in system
Liquid line/component restricted
Vista de pagina 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 269 270