Multiplex Company, Inc.
Complete System Overview
00218011 Revision B (KAK) 31 July, 2000
50
If you have any questions or comments,
please contact Multiplex Technical Service at (314)256-7777.
McDonalds Portion Control Timer
A common problem associated with the McDonalds style portion control timer is when one size
becomes non-adjustable. This may not be more than the trimming potentiometers being adjusted
out of the usable range. To bring them back into range, all that must be done is to turn the screw
counterclockwise 20 complete turns, and then clockwise:
Number of Complete Turns Medium Large Super-Size
Fast Fill 3 4 5
Standard Fill 5 7 9
This procedure should eliminate the replacement of many good portion control timers.
Volume Adjusting Screws
Regular
Selection
Switch
24 VAC
Power
Manual
Fill Switch
Large
Selection
Switch
Medium
Selection Switch