Multiplex Company, Inc.
Component Parts Workbook
17
00218011 Revision B (KAK) 31 July, 2000
Circulating Pump and Motor
Function of the circulating pump and motor
Circulates coils carbonated water from the refrigeration unit up to the dispensing valves and
back to be re-chilled. This keeps the syrups, water and carbonated water continually chilled.
Failure of the circulating pump and motor
A weak or defective circulating pump or motor will cause warm drinks at the dispensing valves.
Notes:
w Draw about one gallon of carbonated water if temperature drops, replace pump
w Verify motor is turning (check power to the motor)
w Verify coupling key is operational
w Verify pump turns freely
w Check carbonated water strainer (if equiped with machine)
w 100 gallon pump = fast flow system
50 gallon pump = standard flow system
w When a pump goes out it can cause black specks to contaminate the carbonated water
circuit (carbon veins in the pump breaking up) you must flush circuit
How to flush a
contaminatedsystem
1. Take the fittings off the circu-
lating pump.
2. Plug one line.
3. Turn on water.
4. Turn off the water on the
CO
2.
5. Plug other line.
6. Repeat.
Coupling Key
Carbonated
Water Strainer
Comentarios a estos manuales