Installation Requirements
The location selected for the ice machine must meet the following criteria. If
any of these criteria are not met, select another location.
³Must have open site (gravity) drain available (see Water Supply and Drain
Requirements).
³Must have a grounded, polarized electrical power supply on a dedicated
electrical circuit (only appliance on circuit). If GFCI (ground fault circuit
interrupter) is required by your local electrical code, it must be breaker type,
not outlet type.
³Must have cold water supply line available at Ice Machine (see Water Supply
and Drain Requirements).
³Clearance and air temperatures must be met.