Manitowoc CVD2075 Especificaciones Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
Electrical Service
Requirements
³ All electrical work, including wire routing and grounding, must
conform to local, state and national electrical codes. The following
precautions must be observed: The ice machine must be grounded.
³ A separate fuse/circuit breaker must be provided for each
condensing unit.
³ A qualified electrician must determine proper wire size dependent
upon location, materials used and length of run (minimum circuit
ampacity can be used to help select the wire size).
³ The maximum allowable voltage variation is +/-10 of the rated
voltage at ice machine start-up (when the electrical load is highest).
³ Check all green ground screws in the control box and verify they are
tight before starting the ice machine.
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 51 52

Comentarios a estos manuales

Sin comentarios