Part Number STH12 9/10 81
Press and hold Carb B switch — Display will
indicate one of the following:
Cb00 — Low and High Probes are open
(carbonator motor is energized)
Cb11 — Low and High Probes are closed
(carbonator motor is de-energized)
Cb01 — Low Probe closed (Motor will still be
on)
Press and hold COMP/AGIT switch — Display will
indicate one of the following:
CL 0 — Water level low
CL 1
— Water level OK
Program Mode 2
Add circulation pumps C & D.
Press PGM button for 3 seconds — Display shows
0001.
Press PGM button — Display shows 0002
program mode 2.
Wait 3 seconds — Display shows -002 = Factory
default setting.
Pressing CIRC A button
energizes/de-energizes pump A
Pressing CIRC B button
energizes/de-energizes pump B
Program CIRC C — Press CARB A button –
Display shows -102 = Carb A button
energizes/de-energizes pump C
Program CIRC D — Press CARB B button -
Display shows -012 = Carb B button
energizes/de-energizes pump D
Press and hold PGM switch for 3 seconds to save