26 Part Number 000007661 7/11
ICE CHUTE REMOVAL - RFS MODELS
RFS0300/RFS0650/RF1200/RF2300 Only
1. Place the toggle switch in the OFF position, turn
off the water supply and disconnect electrical
power to the ice machine.
2. Disconnect water supply.
3. Remove water reservoir cover.
4. Remove microswitch and bin thermostat from the
ice chute.
5. Remove retainer, ice chute elbow and ice chute.