Part Number 000007661 6/12 117
Charts
Ice Production & Refrigerant Pressure
These charts are used as guidelines to verify correct
ice machine operation.
Accurate collection of data is essential to obtain the
correct diagnosis.
Zero out manifold gauge set before obtaining
pressure readings to avoid misdiagnosis.
Discharge and suction pressure are highest at the
beginning of the cycle. Allow system to stabilize for
a minimum of 10 minutes, then verify the
pressures are within the range indicated.
Water temperature will affect suction and
discharge pressure - 50°F (10°C) water
temperature will result in pressures on the lower
end of the ranges specified. 90°F (32°C) water
temperatures will result in pressures on the upper
end of the range specified.