Manitowoc Q130 Especificaciones Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
Section 3 Operation
Part Number 000001130 12/08 3-3
Energized Parts Chart
* Condenser Fan Motor: The fan motor is wired through a fan cycle pressure control, therefore, it may cycle on and off.
CONTROL BOARD RELAYS RELAY
12 3 3A 3BLENGTH
WATER
PUMP
HOT GAS
VALVE
RELAY
COIL
COMPRESSOR
CONDENSER
FAN MOTOR
of “ON” TIME
INITIAL START-UP/
START UP AFTER
AUTO SHUT-OFF:
1. Pressure
Equalization
OFF ON OFF OFF OFF
15
Seconds
2. Refrigeration
System Start-up
OFF ON ON ON ON
5
Seconds
FREEZE
SEQUENCE:
3. Pre-Chill
OFF OFF ON ON ON
30
Seconds
4. Freeze ON OFF ON ON ON
Until 7 sec.
water contact
with ice
thickness
probe
HARVEST
SEQUENCE:
5. Harvest
OFF ON ON ON ON
Bin switch
activation
AUTOMATIC SHUT-
OFF:
6. Auto Shut-Off
OFF OFF OFF OFF OFF
Until
bin switch
re-closes
Vista de pagina 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 39 40

Comentarios a estos manuales

Sin comentarios