Manitowoc Q210 Manual de servicio Pagina 139

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 175
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 138
Section 7 Refrigeration System
Part No. 80-1100-3 7-27
HARVEST PRESSURE REGULATING
(H.P.R.) SYSTEM
Remotes Only
GENERAL
The harvest pressure regulating (H.P.R.) system
includes:
Harvest pressure regulating solenoid valve (H.P.R.
solenoid). This is an electrically operated valve which
opens when energized, and closes when de-
energized.
Figure 7-12. H.P.R. Solenoid
Harvest pressure regulating valve (H.P.R. valve).
This is a non-adjustable pressure regulating valve
which modulates open and closed, based on the
refrigerant pressure at the outlet of the valve. The
valve closes completely and stops refrigerant flow
when the pressure at the outlet rises above the valve
setting.
Figure 7-13. H.P.R. Valve
SV1427
INLET OUTLET
FLOW
SV3053
OUTLET
INLET
Vista de pagina 138